Chemical Analysis Laboratory

- Agilent 1100 HPLC
- Diode array detector (DAD) and Sedex model 75 evaporative light scattering detector (ELSD)
- Separation, quantification of non-volatile organic compounds
- Agilent 6890N GC
- Flame ionization detector (FID)
- Quantification of volatile organic compounds

- Agilent 6890N GC/5973 MSD
- Single quadrupole mass analyzer
- Electron impact (EI) and chemical ionization (CI) sources
- Mass range (m/z) up to 800
- Molecular weight determination
- Identification and quantification of volatile organics

- Agilent 1100 LC/MS (SL)
- Single quadrupole mass analyzer
- API-ESI and APCI ionization sources
- Mass range (m/z) up to 3000
- Non-volatile organics, peptide, protein analysis
- Deconvolution software

- Beckman Du-7500 UV-Vis Spectrophotometer
- Temperature controller (0-110° Celsius)
- Wavelength range of 190 to 800nm
- Kinetics studies

- Agilent 8453 UV-Vis Spectrophotometer
- UV-vis spectra of 190-1100 nm
- Temperature range (10-110° C)
- Quantitative analysis for UV-Vis absorbing materials

- Waters PrepLC 4000 system with tunable absorbance detector
- Purification of organic compounds from few hundreds of milligrams to few grams
- Up to four solvents
- Flow range programmable from 0.5 to 150 ml/min
- Millennium 32 software

- Waters 600E LC with PAD detector
- Up to four solvents
- Flow programmable, isocratic or gradient
- Flow rate range 0.00 to 20.00 ml/min
- Wavelength range 190 to 800 nm
- Millennium 32 software
- Separation and quantification of non-volatile organic compounds
- Malvern Zetasizer Nano-S
- Particle size distribution measurement (0.6 nm to 6 micron)
- Molecular weight measurement (1x10ˆ3 to 2x10ˆ7 Da)
- Temperature range of 2 to 90° Celsius

- Brookhaven BI-200SM Multi-angle Light Scattering System
- Both dynamic light scattering (DLS) and static light scattering (SLS)
- Angular range: 8-155 º
- He/Ne laser (632.8 nm)
- Highly efficient BI9000 AT autocorrelator containing 522 selectable channels
- Measurements of particle size and size distribution
- Mw, Rg, A2 for dilute polymer solutions
- CONTIN, Zimm, Guinier and Fractal analysis

- Jasco J-810 Circular Dichroism Chiroptical Spectrometer
- CD/ORD spectra for optically-active compounds
- Temperature range: -4 to 110 °C
- Protein folding studies
- Protein conformational studies
- Organic stereochemistry studies
- Purity testing of optically active substances
- Wavelength range 163 nm to 1100 nm
- SFM-20 Jasco/Bio-logic 2-syringe stopped-flow system

- Thermo Nicolet Almega XR Raman Microscope
- A confocal Raman microscope
- 10x, 20x, 50x and 100x objectives
- 532 nm and 785 nm lasers with CCD detector
- Microscope stage resolution of 0.1 micron

- Varian FTS 7000 FT-IR Imaging System
- DTGS detector for bulk sample measurement
- Single element MCT and FPA MCT detectors (Focal Plane Array) (64x64, takes 4096 spectra at the same time over 350x350 micron area)
- Covers 5000 cm-1 to 950 cm-1 for MCT detectors
- Grazing angle objective and 36x Cassegrain objective