Preface: Masterformat 07 21 13.19, Preformed Mineral-Fibre Insulation
- Preface Issued:
- 2008-02-19
Scope
These Evaluation Listings apply to mineral-fibre thermal insulation in the form of batts, blankets, boards and sheets, with or without membranes. The proponent has demonstrated that the product meets the following standard:
- CAN/ULC-S702-97, Standard for Mineral Fibre Thermal Insulation for Buildings.
The standard describes five types of mineral-fibre insulation. These CCMC Evaluation Listings refer only to preformed insulation, Types 1, 2 and 3. They are defined as follows:
- Type 1, which has no membrane;
- Type 2, which has a permeable membrane; and
- Type 3, which has a vapour barrier.
The Standard does not apply to insulation less than 25 mm thick, or to preformed insulation used above a roof deck.
Standard
| Test/Property | Units | Requirements | ||
|---|---|---|---|---|
| Thermal resistance | (m2·K)/W | mean thermal resistance ≥ the design thermal resistance (as stated on the product) | ||
| Thermal resistivity | (m·k)W | ≥ 18.5/m | ||
| Thickness | mm | mean thickness ≥ the design thickness and none of the individual specimen thicknesses < 90% of the design thickness; -1, +3 for boards and sheets | ||
| Width | % | -0, +3 for batts and rolls; and | ||
| mm | ± 3 for boards and sheets | |||
| Length | % | -1,+3 for batts and rolls; and | ||
| mm | -3, +10 for boards and sheets | |||
| Surface burning | flame-spread classification | no unit | ≤ 25 | (both applicable to Type 1 product but not intended for exterior of basement walls) |
| smoke developed | ≤ 50 | |||
| Smoulder resistance | % | mean loss ≤ 5 and each specimen ≤ 10 (applicable only to Type 1 product, not intended for exterior of basement walls) | ||
| Breaking load of exterior frame wall sheathing | kg | 2.7 (applicable only to Type 2 boards and sheets for exterior wall sheathing) | ||
| Compressive resistance of draining insulation | kPa | ≥ 7 for greater than 38 mm) or | ||
| ≥ 10 (for less than 38 mm) | ||||
| Water vapour permeance | ng/(Pa·s·m2) | not applicable for Type 1 product; | ||
| ≥ 300 for Type 2 product; | ||||
| ≤ 60 for Type 3 product; and | ||||
| value for boards and batts as for coresponding type of batt or roll | ||||
Labelling
The standard requires that packaging for the insulation be identified with the following information:
- brand name and the name of the manufacturer or supplier;
- identification of the manufacturing facility location;
- type of insulation and its intended use;
- net content of package in m2;
- design linear dimensions of the pieces in the package in mm;
- design thickness in mm;
- thermal resistance in (m2·K)/W to one decimal place;
- on batts and rolls, the numerical thermal resistance value (or a simple code) displayed on the material at
- every 1.2 m length;
- date of manufacture or shift code;
- statement that the product complies with the standard; and
- for preformed insulation without a membrane, a cautionary statement as follows: "CAUTION: Maintain building, electrical, gas and oil safety code required clearances between the insulation and heat-emitting devices, such as fuel-burning appliances, chimneys, pipes, ducts and vents to these appliances (at least 50 mm) and recessed light fixtures (at least 75 mm)."
Where applicable, the product shall carry additional information as stated below:
- if the product is intended for application at thicknesses other than the design thickness, the thermal resistance for each intended installed thickness shall be shown. These thermal resistance values and thicknesses shall be given equal prominence on the packaging and the units used shall be consistent;
- the thermal resistance values and the corresponding thicknesses shall also be displayed on the material at every 1.2 m length (alternatively a simple code may be used);
- any necessary user safety information, unless a separate information sheet is provided; and
- any additional information required by applicable acts and regulations.
National Building Code of Canada (NBC)
NBC References
The CAN/ULC-S702-97 standard is referenced in:
- NBC 1995 (April 2002 Revisions and Errata), Clause 5.3.1.2.(2)(j), Table 9.23.16.2.A. and Clause 9.25.2.2.(1)(g).
- NBC 2005, Division B, Table 5.10.1.1., Table 9.23.16.2.A. and Clause 9.25.2.2.(1)(d).
Evaluation Listing CCMC 05650-L: Fiberglas Pink Home Insulation
- Evaluation Issued:
- 1984-04-11
- Re-evaluated:
- 2010-11-03
- Revised:
- 2010-12-24
- Re-evaluation due:
- 2014-02-08
- Re-evaluation in progress
- Yes
1. Evaluation
The product conforms to CAN/ULC-S702-97, Type 1.
The design thermal resistance values are:
| Design Thickness (mm) | Design RSI (m2·K/W) |
|---|---|
| 65 | 1.4 |
| 89 | 2.11 |
| 92 | 2.11Table ? footnote 1 |
| 89 | 2.29 |
| 89 | 2.47 |
| 92 | 2.47 |
| 140 | 3.87 |
| 152/140Table ? footnote 2 | 3.5/3.34 |
| 159Table ? footnote 3 | 3.5 |
| 152Table ? footnote 4 | 3.96 |
| 152/140 | 4.23 |
| 216 | 4.93 |
| 241 | 5.4 |
| 267 | 6.1 |
| 279 | 7.00 |
| 30Table ? footnote 4 | 7.00 |
Notes to Table:
- Footnote 1
-
Fairburn, Georgia plant only produces the RSI 2.11/89-mm sized roll and blanket insulation.
- Footnote 2
-
The 152-mm/140-mm thickness refers to an uncompressed 152-mm batt or to such a batt compressed to 140 mm.
- Footnote 3
-
Produced at the Edmonton plant only.
- Footnote 4
-
Produced at the Scarborough plant only.
2. Description
A Type 1, mineral fibre thermal building insulation that is available in various sizes of friction-fit batts and roll blanket packages.
3. Standard and Regulatory Information
See the Preface and the standard for explanation.
Listing Holder
Owens Corning Canada Inc.
3450 McNicoll Avenue
Scarborough, ON M1V 1Z5
- Telephone:
- 800-988-5269
- Fax:
- 800-989-8298
- Web:
- www.owenscorning.ca
Plant(s)
Scarborough, ON
Edmonton, AB
Delmar, NY, U.S.A.
Fairburn, GA, U.S.A.
Disclaimer
This Listing is issued by the Canadian Construction Materials Centre, a program of NRC Construction at the National Research Council of Canada. The Listing must be read in the context of the entire CCMC Registry of Product Evaluations.
Readers must confirm that the Listing is current and has not been withdrawn or superseded by a later issue. Please refer to the CCMC web site, or contact the Canadian Construction Materials Centre, NRC Construction, National Research Council of Canada, 1200 Montreal Road, Ottawa, Ontario, K1A 0R6. Telephone (613) 993-6189. Fax (613) 952-0268.
NRC has evaluated the material, product, system or service described herein only for those characteristics stated herein. The information and opinions in this Listing are directed to those who have the appropriate degree of experience to use and apply its contents. This Listing is provided without representation, warranty, or guarantee of any kind, expressed, or implied, and the National Research Council of Canada (NRC) provides no endorsement for any evaluated material, product, system or service described herein. NRC accepts no responsibility whatsoever arising in any way from any and all use and reliance on the information contained in this Listing. NRC is not undertaking to render professional or other services on behalf of any person or entity nor to perform any duty owed by any person or entity to another person or entity.
- Date modified: